MSR additional modules ("plug-in modules")

You can put together your custom MSR unit from a wide range of different measurement modules. The following two measurement modules are already included in the standard MSR basic unit:

  • Module PR3 measures air pressure and ambient air temperature
  • Module ACC3 is a 3-axis accelerometer

The MSR can be upgraded individually using the modules listed below. Should one of your required measurement parameters not be listed, then please contact us for further information. We will be happy to advise.
The following MSR plug-in modules are already in daily use:

Humidity
T24HUM8 The T24HUM8 additional module for the MSR processes and logs the values measured by external temperature or humidity sensors.
A2D5HUM1 The A2D5HUM1 plug-in module records two input voltages, the level of five digital inputs, the signal from one humidity sensor and the temperature of the humidity sensor. Either the instantaneous value or the average, minimum and maximum values can be logged. In addition, a threshold value can be set and an event triggered should this threshold be exceeded.
Temperature
T24HUM8 The T24HUM8 additional module for the MSR processes and logs the values measured by external temperature or humidity sensors.
Air pressure
PR8 The PR8 pressure module processes and logs pressure and temperature values from external pressure sensors.
Fluid pressure
PR8 The PR8 pressure module processes and logs pressure and temperature values from external pressure sensors.
AIN4-10 The universal module AIN4-10 records and logs four input voltages. For prototyping applications this unit can also be used with additional inputs and outputs. The firmware can easily be modified to suit the required application.
AIN4-12 This universal module is particularly suited to prototyping applications. It has a range of analogue and digital inputs and outputs. The firmware can easily be modified to suit the required application.
Compressed air/valve-tester
Valve-tester The valve tester measures the delay time between the control pulse and the output signal. It logs this time together with the value of the output signal and a time stamp. In addition, the delay time is analysed.
3-Axis acceleration
3ACCF The 3ACCF accelerometer module processes and logs measurements from an external acceleration sensor.
Voltage/Current (el.)
AIN4-10 The universal module AIN4-10 records and logs four input voltages. For prototyping applications this unit can also be used with additional inputs and outputs. The firmware can easily be modified to suit the required application.
AIN4-12 This universal module is particularly suited to prototyping applications. It has a range of analogue and digital inputs and outputs. The firmware can easily be modified to suit the required application.
A2D5HUM1 The A2D5HUM1 plug-in module records two input voltages, the level of five digital inputs, the signal from one humidity sensor and the temperature of the humidity sensor. Either the instantaneous value or the average, minimum and maximum values can be logged. In addition, a threshold value can be set and an event triggered should this threshold be exceeded.
ECG
ECG This plug-in module serves to record an ECG signal. The unit can also compute the pulse (heart rate).
Heart rate (transmitted via radio)
POLAR The HR plug-in module processes and logs the heart rate (pulse) measured by the POLAR transmitter chest strap.

All additional modules can be freely combined with one-another. We would be pleased to advise you on our existing standard module combinations.

The range of sensors is under continuous development and will be adapted to meet customers' requirements. Plug-in modules are planned or under development for the following fields:

  • Blood pressure
  • Breathing pattern
  • Field strength
  • Force-displacement (strain gauge)
  • Gas analysis
  • Position (GPS)
  • Pulse
  • Speech/sound recording
  • SPO2 (oxygen)
  • Velocity
 


 
 
 
USA Office

Tel:1.877.902.2979-1.425.223.4311
Fax:1.877.329.4324
Address: 1480 Gulf Road, Suite 837,
PO Box 1364
Point Roberts, WA 98281

Western Canada - Vancouver BC

Tel:1.800.663.6001 or 1.604.925.6150
Fax:1.604.925.6170
Address: 2454 Haywood Ave
West Vancouver, BC V7V 1Y1

Eastern Canada - Markham, Ontario

Tel:1.800.465.0164 or 1.905.513.7027
Fax:1.877.329.4324