Tinytag connectors allow you to attach your own input lead or probe to certain Tinytag data loggers. The 2-pin plug will connect a third-party input lead to a Tinytag current, voltage or count data logger. The 5-pin plug will connect a third-party PT100 or PT1000 probe to compatible temperature data loggers. It can also be used to connect an input lead to some voltage and current loggers.
Spare Connector -ACS-9700 2-pin connector plug for TGPR-0804, TGPR-1001, TGPR-1201, TR-1201, TR-3804, TGRF-4901, TGRF-4904, TGRF-4804 and TGRF-4844
A 2-pin plug to attach your own input lead to the Tinytag current, millivolt and count data loggers.
Spare Connector -ACS-9703 5-pin connector plug to connect an input lead or your own probe/sensor
A 5-pin plug which can be used to connect your own input lead for the following Tinytag voltage and current data loggers: TGPR-0704, TV-4704, TV-4804, TR-3703, TR-3704, TGRF-4101,TGRF-4102, TGRF-4201, TGRF-4202
It can also be used to connect your own PT100/PT1000 probe/sensor with the following loggers: TGP-4104, TGP-4204, TV-4104, TV-4204, TR-3101, TR-3201, TGRF-4101, TGRF-4102, TGRF-4201, TGRF-4202
Spare Input Leads
These input leads are compatible with Tinytag current, voltage, millivolt and count data loggers. They are supplied with the data loggers so separate ordering is only needed when spares are required.
Voltage/current input lead for Talk loggers (TK-4702, TK-4703 and TK-4802)
This 3-wire cable for the Talk 2 voltage and current data loggers comes with a 1.5m cable and weighs 27g.
Spare Input Lead - CAB-3239
Input lead for current/voltage loggers (TGP-4703, TGP-4704, TGP-4804, TV-4703, TV-4704, TV-4804, TGPR-0704, TR-3703, TR-3704, TGRF-4703, TGRF-4743, TGRF-4704 and TGRF-4744)
This 5-wire cable for certain Tinytag current and voltage data loggers comes with a 1.5m cable and weighs 50g.
Spare Input Lead - CAB-3246
Input lead for current, millivolt and count loggers (TGPR-0804, TGPR-1001, TR-3804, TGPR-1201, TGRF-4901, TGRF-4904, TGRF-4801, TGRF-4844 and TGP-4901)
This 2-wire cable for Tinytag current, count and millivolt data loggers comes with a 1.5m cable and weighs 30g
USA Office
Tel:1.877.902.2979-1.425.223.4311
Fax:1.877.329.4324
Address: 1480 Gulf Road, Suite 837,
PO Box 1364
Point Roberts, WA 98281
Western Canada - Vancouver BC
Tel:1.800.663.6001 or 1.604.925.6150
Fax:1.604.925.6170
Address: 2454 Haywood Ave
West Vancouver, BC V7V 1Y1
Eastern Canada - Markham, Ontario
Tel:1.800.465.0164 or
1.905.513.7027
Fax:1.877.329.4324