TC-08 USB - PP222
Thermocouple Data Logger

Converts PC to Oscilloscope (1435 bytes)

    TC-08 thermocouple data logger


US Prices
CDN Prices

Privacy and Security

 

 

 
 
 
Temperature measurement and recording with the TC-08 is very easy — simply plug the TC-08 into a USB port on your computer, plug in your thermocouples, and you are ready to go.
 


 

The TC-08 thermocouple data logger offers industry-leading performance and a cost-effective solution to your temperature measuring needs.
  • 8 channel thermocouple data logger
  • Measures from -270 to 1820 °C
  • Automatic cold junction compensation
  • High resolution and accuracy
  • Fast sampling rate
  • Multiple units can be run on a single PC
  • USB interface
 

Wide temperature range

The TC-08 thermocouple data logger is designed to measure a wide range of temperatures using any thermocouple that has a miniature size thermocouple connector. Additionally, the TC-08 can also measure other sensors using a 70 mV range.

Featuring built-in cold junction compensation (CJC), the TC-08 has an effective temperature range of -270 to 1820 °C (The actual temperature range depends on the thermocouple being used.)

 
Fast and accurate temperature data acquisition

With the TC-08 thermocouple data logger your temperature measurements can be made both fast and accurately.

The short conversion time of the TC-08 means up to 10 temperature measurements can be taken every second (cold junction compensation counts as an additional measurement), while the high (20-bit) resolution ensures that the TC-08 can detect minute changes in temperature.  For popular Type K thermocouples the TC-08 can maintain a better than 0.025°C resolution over a –250 to 1370 °C range.
 

Also measure voltage and 4–20 mA current loops!

As well as measuring temperature with thermocouples, the terminal board allows other sensors with voltage or current outputs to be connected.  

The optional Single-Channel Terminal Board PP624 (see Accessories) plugs into a channel on the TC-08 and turns it into a 20-bit high resolution data logger. Screw terminals allow wires to be attached to the data logger without soldering. The four input ranges (±50mV, ±500 mV, ±5 V and 4–20 mA) allows a wide range of other sensors and signals to be measured.
single channel terminal board
PP624 

All you need in one easy-to-use unit

Temperature data acquisition with the TC-08 is very easy — simply plug the TC-08 into a USB port on your computer (no external power required), connect your thermocouples, and you are ready to measure temperatures.

The easy-to-use PicoLog data acquisition software is supplied with the TC-08 — allowing you to start measuring and recording temperatures with the minimum effort. The intuitive user interface of PicoLog makes it easy for you to set how frequently you want to take a measurement, and the number of measurements you want to take.

Need more?...

If you need more than 8 channels just plug two TC-08s into your PC to make a "TC-16".  Using a USB hub up to 20 TC-08s can be used on one PC for a total of 160 channels. You can even mix and match different data loggers from the Pico range to build a flexible, expandable data acquisition system.

 

PicoLog Software

PicoLog 6 is a complete data acquisition software package for the Pico Technology ADC-20 and 24 precision voltage input data loggers. It provides a visual, easy-to-use interface for users to quickly set up simple or complex acquisitions, record, view and analyze data.
 
  • Real-time data collection and display
  • Visual logger and channel setup for easy configuration and viewing
  • Available for Windows 7, 8 and 10 (32 and 64-bit), macOS and Linux
  • Virtually unlimited logging capacity to PC
  • Robust database format minimizes data loss and corruption
  • Simple and complex programmable alarms
  • Up to 4 independent graph axes
  • Channels can be scaled using lookup table or equation
  • Data can be exported as CSV, clipboard image and PDF
  • Supports multiple different PicoLog data loggers on the same PC
 

More information on PicoLog 6 data logging software >>

 


 

USB TC-08 Manuals
 

Resource Language Version Size Updated
Data Sheet:
USB TC-08 Data Sheet English 6 1 MB December 13 2016
User's Guides:
USB TC-08 User’s Guide English 8 545 KB May 03 2016
USB TC-08 Terminal Board User’s Guide English 1 99 KB September 14 2009
PicoLog User’s Guide English 5 2 MB February 17 2014
Programmer's Guides:
USB TC-08 Programmer’s Guide English 6 740 KB May 24 2016
USB Data Logger Installation Guide English
Français
Deutsch
Italiano
Español
中文 (简体)
Nederlands
Dansk
Svenska
7 400 KB January 17 2012
Training Guides:
PicoLog Frequently Asked Questions English 2 932 KB October 10 2016


 

USB TC-08 Accessories
 

Sensors
Product Price
Single-channel TC-08 terminal board
PP624
Recommended
Thermocouple type K, air, 4.5 mm tip
SE002
Recommended
Thermocouple type K, exposed tip, glass fibre insulated, 1 metre
SE001
Recommended
Thermocouple type K, exposed tip, glass fibre insulated, 2 metre
SE030
Recommended
Thermocouple type K, exposed tip, glass fibre insulated, 5 metre
SE031
Recommended
Thermocouple type K, exposed tip, PTFE insulated, 1 metre
SE000
Recommended
Thermocouple type K, exposed tip, PTFE insulated, 10 metre
SE029
Recommended
Thermocouple type K, exposed tip, PTFE insulated, 2 metre
SE027
Recommended
Thermocouple type K, exposed tip, PTFE insulated, 3 metre
SE028
Recommended
Thermocouple type K, insertion, 3.3 mm tip
SE003
Recommended
Thermocouple type K, ribbon surface, 8 mm tip
SE004
Recommended
Miscellaneous
USB 2.0 cable, 1.8 m
MI106
  Calibration certificate for thermocouple loggers
CC001
Recommended
USB 2.0 cable, 4.5 m
MI121


 

Specifications

USB TC-08 Thermocouple Data Logger general specifications
Number of channels 8
Conversion time 100 ms (thermocouple and cold junction compensation) 
(CJC can be disabled if all channels used as voltage inputs)
Temperature accuracy Sum of ±0.2 % of reading and ±0.5 °C
Voltage accuracy Sum of ±0.2 % of reading and ±10 µV
Overload protection ±30 V
Maximum common mode voltage ±7.5 V
Input impedance 2 MΩ
Input range (voltage) ±70 mV
Resolution 20 bits
Noise free resolution 16.25 bits
Thermocouple types supported B, E, J, K, N, R, S, T
Input connectors Miniature thermocouple
Output connector USB — cable supplied
PC connection USB 1.1
Power supply from USB port
Dimensions 201 x 104 x 34 mm
Supplied software PicoLog data acquisition software
Driver and examples (C, Delphi and Visual Basic, Labview, Agilent VEE6.1 and Excel)
Software is supplied on CD and is compatible with Windows 98SE/ME/2000/XP/Vista
Maximum number of channels
(using up to 20 TC-08s)
160

 

PC requirements
Minimum Processor: 1 GHz.
Memory: 512 MB.
Free disk space: 32–bit: 600 MB, 64–bit: 1.5 GB.
Operating system: 32– or 64–bit edition of Microsoft Windows XP (SP3), Vista, Windows 7, Windows 8 (not Windows RT) or Windows 10.
Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, OS X (Mac).
Ports: USB 1.1 port.
Recommended Processor: 1 GHz.
Memory: 512 MB.
Free disk space: 32–bit: 850 MB, 64–bit: 2 GB.
Operating system: 32– or 64–bit edition of Microsoft Windows 7, Windows 8 (not Windows RT) or Windows 10.
Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, OS X (Mac).
Ports: USB 1.1 or higher.

 

Environmental
Operating temperature 0 to 50 °C
Operating temperature for stated accuracy 20 to 30 °C
Operating humidity 5 to 80 %RH non-condensing
Storage humidity 5 to 95 %RH non-condensing
Water resistance Not water-resistant

 

Physical properties
Dimensions 201 x 104 x 34 mm (7.91 x 4.09 x 1.34 in)

 

Software
PicoLog for Windows PicoLog data acquisition software can collect up to 1 million samples. Features include:
Multiple views — view data as a graph, spreadsheet or text
Parameter scaling — convert raw data into standard engineering units
Math functions — use mathematical equations to calculate additional parameters
Alarm limits — program an alert if a parameter goes out of a specified range
IP networking — transfer measurements via a LAN or over the Internet
Operating systems supported — Microsoft Windows XP (SP3) to Windows 10. Not Windows RT.
PicoLog languages Full support for: English, Français, Deutsch
Menus and dialogs only for: Italiano, Español, Svenska
Software Development Kit Includes example code.
Optional free software Drivers for Linux and OS X. 32-bit and 64-bit.

 

Documentation languages
User’s guide
Programmer’s guide
Installation guide
English
English
English, Français, Deutsch, Italiano, Español, Svenska, Nederlandse, Dansk

 

General
Additional hardware (supplied) USB 2.0 cable, user manuals, software CD-ROM
PC interface USB 1.1
Power requirements Powered from USB port
Compliance European EMC and LVD standards
FCC Rules Part 15 Class A
Total satisfaction guarantee In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days.
Warranty 5 years


TC-08 Resolution

Thermocouple type Overall range °C 0.1°C resolution 0.025°C resolution
B 20 to 1820 150 to 1820 600 to 1820
E -270 to 910 -270 to 910 -260 to 910
J -210 to 1200 -210 to 1200 -210 to 1200
K -270 to 1370 -270 to 1370 -250 to 1370
N -270 to 1300 -260 to 1300 -230 to 1300
R -50 to 1760 -50 to 1760 20 to 1760
S -50 to 1760 -50 to 1760 20 to 1760
T -270 to 400 -270 to 400 -250 to 400
 

Applications for the TC-08

The TC-08 thermocouple data logger is used successfully throughout the industrial, scientific, medical and the food industries; listed here are some interesting applications:

  • Generation of electricity from biomass — an investigation by the UK government into renewable energy sources
  • Espresso coffee grinder testing — how the TC-08 is helping to make the perfect Espresso
  • See our thermocouples application note

Order your TC-08 Data Logger

 


 

Type T Thermocouple

All our sensors have been carefully selected to offer high performance at a low cost.

 

Type T Thermocouple Thermocouple type T, 4 mm x 50 mm stainless steel waterproof tip, 10 m
SE058
Type T Thermocouple Thermocouple type T, 4 mm x 50 mm stainless steel waterproof tip, 3 m
SE056
Type T Thermocouple Thermocouple type T, 4 mm x 50 mm stainless steel waterproof tip, 5 m
SE057
Type T Thermo Thermocouple type T, exposed tip, fiberglass insulated, 1 m
SE051
Type T Thermo Thermocouple type T, exposed tip, fiberglass insulated, 10 m
SE055
Type T Thermo Thermocouple type T, exposed tip, fiberglass insulated, 2 m
SE052
Type T Thermo Thermocouple type T, exposed tip, fiberglass insulated, 3 m
SE053
Type T Thermo Thermocouple type T, exposed tip, fiberglass insulated, 5 m
SE054
Type T Thermocouple Thermocouple type T, exposed tip, PTFE insulated, 1 m
SE046
Type T Thermocouple Thermocouple type T, exposed tip, PTFE insulated, 10 m
SE050
Type T Thermocouple Thermocouple type T, exposed tip, PTFE insulated, 2 m
SE047
Type T Thermocouple Thermocouple type T, exposed tip, PTFE insulated, 3 m
SE048
Type T Thermocouple Thermocouple type T, exposed tip, PTFE insulated, 5 m
SE049
 
 
 
 
USA Office

Tel:1.877.902.2979-1.425.223.4311
Fax:1.877.329.4324
Address: 1480 Gulf Road, Suite 837,
PO Box 1364
Point Roberts, WA 98281

Western Canada - Vancouver BC

Tel:1.800.663.6001 or 1.604.925.6150
Fax:1.604.925.6170
Address: 2454 Haywood Ave
West Vancouver, BC V7V 1Y1

Eastern Canada - Markham, Ontario

Tel:1.800.465.0164 or 1.905.513.7027
Fax:1.877.329.4324