website security


PicoLog 1000 Series

pico logo
  US Prices
CDN Prices

Privacy and Security Policy

 

multiple channel data acquisition

Multichannel data acquisition (DAQ)
 

  • Up to 16 input channels per data logger
  • Up to 4 output channels per data logger
  • Use up to 4 data loggers at the same time
  • Up to 1 MS/s sample rate
  • USB connected and powered
  • Data acquisition software and SDK included

 

A distinguished pedigree

The PicoLog 1000 Series is the result of a distinguished lineage that goes back to the release of our first multi-channel data logger - the ADC-11 - in 1993. The original ADC-11, and its successor the USB ADC-11, proved to be the perfect choice for users wanting a low-cost way to measure and record multiple signals. The PicoLog 1000 Series builds on this success to give you the same low-cost data acquisition but with greater power and performance. (Because the ADC-11 was so popular we've also added a USB ADC-11 compatibility mode which allows you to use your PicoLog 1000 logger as a direct replacement to the USB ADC-11.)

An expandable multi-channel data acquisition systemterminal board

The budget model PicoLog 1012 has 12 input channels. The powerful PicoLog 1216 has 16. Need more channels? No problem. Using PicoLog you can connect up to 4 Pico data loggers to one PC - giving you a potential 64 channel PicoLog 1000 Series data acquisition system, or the ability to use your PicoLog 1000 logger with other devices such as the USB TC-08 thermocouple data logger.

 

External Terminal Board


The external terminal board has screw terminals to allow sensor wires to be attached to the data logger without soldering. The terminal board also has locations where you can fit resistors to offset and extend the input ranges of the logger.

 

Fast and accurateMulti Channel Picolog Display

With 10 or 12-bit resolution and multiple sampling modes, a PicoLog 1000 Series logger will meet your data logging needs. The PicoLog 1000 Series has 3 sampling modes: Streaming mode allows channel voltage readings to be logged continuously at up to 100 kS/s, while block mode captures up to the full 1 MS/s sample rate of the logger for a duration limited by the 8000 sample buffer, both these speeds applying to single-channel operation. The PicoLog application provides an extra mode, real-time continuous sampling, which provides averaged, time-accurate readings with automatic measurements at up to 1 kS/s on any number of channels.











 

PicoLog 1000 Software


PicoLog data acquisition software is a powerful but flexible program for collecting, analyzing and displaying data.
 

  • Collect up to 1 million samples
  • Easy and intuitive to use
  • Real-time data collection, analysis and display
  • Programmable alarm limits can be set for each channel
  • Data can be exported to spreadsheets and databases
  • Supports multiple different Pico data loggers on the same PC
  • Uses your PC monitor to give large color display, ideal for education and training
  • Waveforms can be saved, printed or emailed from your PC
  • Supports Windows XP, 7, 8 and 10
 

PicoLog views

PicoLog displays data in a number of views, which can be activated as and when required. These views can be activated both during and after data collection.
 

Recorder view

Enables you to start/stop recording and specify recording files. It shows the current readings and alarm conditions for each channel. All settings such as scaling, channels and sampling are controlled from the recorder view.
 

Spreadsheet view

Displays text data in a format that can be easily copied and pasted into other applications. Data can also be saved to disk in standard ASCII text format.
 

Graph view

Graphs can be displayed both during and after data collection. Each channel can be displayed in its own graph or multiple channels can be displayed in the same graph. Axes can be set up manually, automatically or in chart recorder mode. Multipliers allow you to magnify areas of interest. Graphs can be copied and then pasted into reports.


XY graph view

Displays one parameter against another. Useful for plotting voltage against current, for example.
 

Notes view

Notes view allows you to attach notes to data.
 

Player view

Displays previously recorded data. It enables you to scroll quickly through stored files to compare results on successive runs. The player can be used to examine old data while new data is still being recorded.
 

Exporting data and remote logging


Data can easily be transferred (either as graphs or raw data) to other Windows applications by using the clipboard (copy and paste). Graphs can also be saved to disk (as Windows Metafiles) and data from the spreadsheet can be saved in text format. 

PicoLog data acquisition software also supports IP networking. This enables remote data collection from Pico’s full range of data acquisition products.

 

Scaling and alarms


Parameter scaling can be used to convert raw data into standard engineering units. A wide range of equation and table lookup scaling options are provided.

Additional parameters can be calculated. For example, to calculate power output from a boiler you may need to multiply a flow reading from one channel with the temperature difference between two further channels.

Alarm limits can be set for each channel to alert the user should a parameter go out of a specified range.[High speed data acquisition]Software Development Kit (SDK)

As well as the supplied PicoLog software, also included are drivers and examples for those who want to write your own software or interface to other programs.

Software drivers are supplied for Microsoft Windows, Apple Mac (OS X) and Linux (including Raspberry Pi and BeagleBone).  

Example code shows how to interface to third-party software packages such as Microsoft Excel and National Instruments LabVIEW as well as how to write your own software in C / C#.



 

PicoLog 1000 Manuals




 

PicoLog 1000 Accessories
 

Product Price
  USB 2.0 cable, 1.8 m
MI106
 
  Small terminal board for PicoLog 1000
PP545
 
  Calibration certificate for voltage input data logger
CC008
Recommended
 
  USB 2.0 cable, 4.5 m
MI121
 
  USB 2.0 cable, 0.5 m
TA268
 

PicoLog 1000 Specifications
 

Inputs
Variant PicoLog 1012 PicoLog 1216
Maximum sampling rate
Continuous streaming
Real-time continuous
Block mode#1

100 kS/s single-channel
1 kS/s or greater
1 MS/s single-channel
Buffer memory 8000 samples, shared by all channels
Analog inputs 12#2 16#2
Analog bandwidth (-3 dB) DC to 70 kHz
Input type Single-ended, unipolar
Input voltage range 0 to 2.5 V
Linearity (at 25 °C) 1 LSB
Resolution 10 bits 12 bits
Accuracy 1% 0.5%
Overload protection ±30 V to ground
Input coupling DC
Input impedance 1 MΩ
 
Outputs
Digital output (D0...D3) 2 4#2
Digital outputs (PWM)
period
duty cycle
None 1
100 µs to 1800 µs
Adjustable from 0% to 100% in 1% steps
Digital outputs (all)
logic low voltage
logic high voltage
current limit

100 mV (typical)
3.3 V
1 kΩ resistors in series with outputs
Power output for sensors 2.5 V @ 10 mA, current-limited
 
PC Requirements
Minimum Processor: 1 GHz.
Memory: 512 MB.
Free disk space: 32-bit: 600 MB, 64–bit: 1.5 GB.
Operating system: 32- or 64-bit edition of Microsoft Windows XP (SP3), Vista, Windows 7 or Windows 8 (not Windows RT).
Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, OS X (Mac).
Ports: USB 1.1 port.
Recommended Processor: 1 GHz.
Memory: 512 MB.
Free disk space: 32-bit: 850 MB, 64–bit: 2 GB.
Operating system: 32- or 64-bit edition of Microsoft Windows 7 or Windows 8 (not Windows RT).
Beta software: Linux Debian, OpenSUSE and Fedora derived distributions, Mac OS X.
Ports: USB 1.1 or higher.
 
Environmental
For quoted accuracy 20 °C to 50 °C
General operation 0 °C to 70 °C
Relative humidity 5% to 80% RH
 
Physical Dimensions
Dimensions 45 mm x 100 mm x 140 mm (1.77" x 3.94" x 5.51")
Weight <200 g (7.05 oz)
 
Software
PicoLog for Windows PicoLog data acqusition software can collect up to 1 million samples. Features include:
Multiple views - view data as a graph, spreadsheet or text
Parameter scaling - convert raw data into standard engineering units
Math functions - use mathematical equations to calculate additional parameters
Alarm limits - program an alert if a parameter goes out of a specified range
IP networking - transfer measurements via a LAN or over the Internet
Operating systems supported: Microsoft Windows XP (SP3) to Windows 10. Not Windows RT.
Full details on PicoLog
PicoScope 6 for Windows PicoScope 6 is your complete test and measurement lab in one application. Features include:
Capture modes - oscilloscope, spectrum and persistence modes
Channel maths - calculate the sum, dfference, product, inverse or create your own custom function using standard arithmetic, exponential and trigonometric functions
Automated measurements
Scope mode: AC RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak-to-peak, rise time and rising rate
Spectrum mode: frequency at peak, amplitude at peak, total power, total harmonic distortion (THD), total harmonic distortion plus noise (THD N), spurious-free dynamic range (SFDR), signal noise distortion to signal noise ratio (SINAD), signal to noise ratio (SNR) and intermodulation distortion (IMD)
Export data formats - Comma separated values (CSV), tab delimited (TXT), windows bitmap (BMP), graphics interchange format (GIF), portable network graphics (PNG), MATLAB 4 format (MAT)
Operating systems supported: Microsoft Windows 7, 8 and 10* (not Windows RT).
Full details on PicoScope 6
Software development kit Includes example code.
Optional free software PicoScope 6 Beta for Linux and OS X. Drivers for Linux and OS X.
 
Documentation languages
Documentation
User’s guide
Programmer’s guide
Terminal board user’s guide
English, Français, Deutsch, Español
English
English
 
General
Additional hardware (supplied) USB 2.0 cable, user manuals, software CD-ROM
PC interface USB 2.0 - cable supplied
I/O connector 25-way D female
Power requirements Powered from USB port
Ground fault current protection 0.9 A thermal self-resetting fuse
Compliance European EMC and LVD standards
FCC emissions
RoHS compliant
Total Satisfaction Guarantee In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days.
Warranty 5 years
Lead time 10 working days
  • #1 Block mode is supported by PicoScope and the PicoLog 1000 Series API, but not by PicoLog.
  • #2 Except in USB ADC-11 compatibility mode

order your datalogger

 

Logger Without Terminal Board

          1012 W/O Terminal (PP543)
xxxxxxxx

        1216 W/O Terminal (PP544) 
yyyyyyyy

Logger With Terminal Board

            1012 With Terminal (PP546)
zzzzzzz

        1216 With Terminal (PP547)
aaaaaaaaa

 
 
 
USA Office

Tel:1.877.902.2979-1.425.223.4311
Fax:1.877.329.4324
Address: 1480 Gulf Road, Suite 837,
PO Box 1280
Point Roberts, WA 98281

Western Canada - Vancouver BC

Tel:1.800.663.6001 or 1.604.925.6150
Fax:1.604.925.6170
Address: 2454 Haywood Ave
West Vancouver, BC V7V 1Y1

Eastern Canada - Markham, Ontario

Tel:1.800.465.0164 or 1.905.513.7027
Fax:1.905.513.7029
Address: 3555 14th Ave, Unit 12,
Markham, Ontario L3R 0H5