PicoScope 6.13.1 Beta with DeepMeasure™

pico logo

 

US Prices 
CDN Prices

Privacy and Security Policy

Featured Product
 
picoscope 6000 series, deepmeasure
 

The fastest sampling, highest bandwidth, deepest memory and fastest waveform update rate of any USB oscilloscope on the market today. The PicoScope 6000 Series includes high-end features such as serial decoding, mask limit testing, frequency measurement plotting and segmented memory as standard.

  • 4 channels
  • 500 MHz bandwidth
  • 5 GS/s real-time sampling
  • 2 GS ultra-deep memory
  • 170,000 waveforms per second
  • Arbitrary waveform generator (AWG)
  • USB 3.0 interface

View Deep Measure Product Video

 
xxxxxxxxxx


 

Waveform measurements

Measurement of waveform pulses and cycles is key to verification of the performance of electrical and electronic devices.

DeepMeasure delivers automatic measurements of important waveform parameters on up to a million waveform cycles with each triggered acquisition. Results can be easily sorted, analyzed and correlated with the waveform display.



 
Single-cycle measurements

Oscilloscopes are commonly used to display one, or a few cycles of a waveform, from which it is possible to measure parameters such as cycle time, pulse width, amplitude, rise- and fall-time etc.

On-screen rulers (or cursors) can help to make accurate measurements, and many oscilloscopes offer automated measurements that update with each acquisition.



Multi-cycle measurements
 
In some applications it is necessary to measure the characteristics of waveforms with more than one cycle.
 
Oscilloscopes with deep capture memory and fast sampling, such as the PicoScope 3000 Series (512 MSamples, 1 GS/s) and 6000 Series (2 GSamples, 5 GS/s), can capture waveforms with thousands of cycles at full sampling speed with each triggered acquisition. With this amount of data, it is tedious and error-prone to make successive on-screen measurements manually using rulers, even with the benefit of display zooming and panning. Automated measurements are available on some oscilloscopes, but they are typically limited to just the first full cycle captured in memory or use decimated data.

DeepMeasure

DeepMeasure uses up to 100 million samples to capture the results of every cycle contained in each triggered waveform acquisition.

Results are displayed in a table, with the parameter fields shown in columns and waveform cycles shown in rows. Ten parameters per cycle are included in the first version of the tool and up to a million cycles can be displayed.
  • Cycle time
  • Frequency
  • Low and High pulse width
  • Duty cycle
  • Rise and Fall time
  • Max and Min Voltage
  • Voltage peak to peak
Start and End time, relative to the trigger, are given for each cycle
 

 
Sort and Search

The table of captured results can be sorted by each parameter in ascending or descending order, enabling engineering teams to spot anomalies and rapidly identify the cause of complicated issues. So, for example, click on the Rise Time field heading and you can quickly find the fastest (or slowest) rise time in all of the captured cycles. Double-clicking on a specific measurement highlights and zooms to the corresponding cycle in the oscilloscope view.




 
Export

Captured measurement results can be exported for use with mathematical and statistical functions in tools such as Mathworks MATLAB and Microsoft Excel.


 
Analyze

In this example several hundred measurement results have been plotted in Excel to show frequency of occurrence of each measured frequency in a histogram.



Limitations

DeepMeasure works with up to 100 million samples in each acquisition.
Maximum number of cycles that can be processed in each acquisition is one million. (Not a very severe limitation!)
While running, the number of cycles updated live is limited to 50,000. Additional cycles are processed and displayed when the acquisition is stopped, or with single shot acquisition.
Multiple buffers in PicoScope can be set to trigger and capture successive waveforms; DeepMeasure will process each buffer, up to the 100 million samples total limit.
DeepMeasure works with PicoScope 3000, 4000, 5000 and 6000 Series instruments.



 
 
 
 
USA Office

Tel:1.877.902.2979-1.425.223.4311
Fax:1.877.329.4324
Address: 1480 Gulf Road, Suite 837,
PO Box 1364
Point Roberts, WA 98281

Western Canada - Vancouver BC

Tel:1.800.663.6001 or 1.604.925.6150
Fax:1.604.925.6170
Address: 2454 Haywood Ave
West Vancouver, BC V7V 1Y1

Eastern Canada - Markham, Ontario

Tel:1.800.465.0164 or 1.905.513.7027
Fax:1.877.329.4324