With up to five different sensors, four additional analogue inputs and an easy to read LCD screen the compact MSR255 offers maximum possible flexibility and user-friendliness.
The measuring tasks undertaken by the user define the way in which the MSR255 is configured: There is a choice of temperature, humidity, air pressure and light sensors (fitted internally within the case or externally on a cable) together with a sensor for measuring acceleration in all three co-ordinate axes. Acceleration values can be measured at 3200 Hz and saved at a frequency of approx. 50 Hz following digital filtration. In addition, the voltage of four further external analogue channels or sensors can also be recorded. The analogue inputs feature an alarm output, multiple output switching power supply and an input for starting and stopping data recording.
The memory capacity of the MSR255 is over 2 million measurement parameters. Thanks to its high-capacity lithium polymer battery the data logger is ideal for long-term data acquisition applications. The 4-row backlit LCD display has four individually configurable views. All acquired data can be quickly transferred to a PC or laptop via the USB interface.
With a few clicks you are able to select your desired MSR255.
Housing |
Technical data | Item no. | ||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Standard IP 60 not encapsulated |
|
255B10 Error |
||||||||||||||||||||||||||||||||||||||||||
Waterproof IP 67 encapsulated |
255B11 Error |
You can specify your MSR255 with up to five different sensors.
Measured parameter / Measuring/storage rate |
Working range / Accuracy |
Internal sensor |
External sensor (according to cable length) | ||
---|---|---|---|---|---|
0.20 m | 1.00 m | 1.60 m | |||
Temperature 1/s to every 12 h |
external: -55...+125 °C internal: -20...+65 °C ±0.5 °C (-10...+65 °C) ±2 °C (-55...+125 °C) |
Item no. T2 Error |
Item no. FT2/020 Error |
Item no. FT2/100 Error |
Item no. FT2/160 Error |
Relative humidity with integrated temperature 1/s to every 12 h |
0...100 % rel. humidity external: -20...+85 °C internal: -20...+65 °C ±2 % rel. humidity (10...85 %, 0...+40 °C) ±4 % rel. humidity (85...95 %, 0...+40 °C) |
Item no. H Error |
Item no. FH/020 Error |
Item no. FH/100 Error |
Item no. FH/160 Error |
Air pressure absolute, with integrated temperature 1/s to every 12 h |
0...2000 mbar absolute external: -20...+85 °C internal: -20...+65 °C ±2.5 mbar (750...1100 mbar absolute, +25 °C) |
Item no. P Error |
Item no. FP/020 Error |
Item no. FP/100 Error |
Item no. FP/160 Error |
0...14 bar absolute -20...+65 °C ±50 mbar (1...10 bar abs., +25 °C) |
Item no. P2 Error |
Item no. FP2/020 Error |
Item no. FP2/100 Error |
Item no. FP2/160 Error |
|
3-axis-acceleration Acceleration: 50/s (3200/s) Attitude: 1/s to every 12 h |
±15 g -20...+65 °C ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C) |
Item no. A Error |
Item no. FA/020 Error |
Item no. FA/100 Error |
Item no. FA/160 Error |
Light 1/s to every 12 h |
0...65 000 lx max. sensitivity at 500 nm |
Item no. L Error |
Item no. FL/020 Error |
Item no. FL/100 Error |
Item no. FL/160 Error |
It is possible to expand the range of possible applications for which your MSR255 can be used by specifying four analogue inputs. These additional inputs allow external sensors for a wide range of measuring tasks to be connected. If required, these third-party sensors can be powered by the logger's internal battery. The power can be automatically turned on before measurements take place with a pre-settable lead time. This allows any necessary warm-up periods for the sensors to be taken into consideration.
Analogue inputs | Inputs | Input configuration | Item no. |
---|---|---|---|
Including an alarm output, multiple output switching power supply and an input for starting and stopping data recording. Measurement/storage rate: 1/s to every 12 h |
4 analogue inputs (resolution: 12 bit) |
0...3.0 V - Standard |
E3333 Error |
4 analogue inputs (resolution: 12 bit) |
Select the number of inputs for the respective input configuration: (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0.5...4.5 V / 0...5.0 V (5) 0...10.0 V / 1.0...6.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V |
Exxxx Error |