Four integrated analogue inputs, a high measurement rate of up to 1000/s per channel and its gigantic memory capacity, all packed into a small format are the key characteristics of the MSR160 data logger. The analogue inputs of the robust mini logger can be used for conventional sensors with analogue outputs (e.g. CO2, conductivity, pH etc). In addition, a multiple output switching power supply is also provided.
The rugged quality data logger records over 2 000 000 measurement parameters. With the optional microSD card you can expand the memory capacity of your MSR160 to over one billion measurement parameters. All saved data can be rapidly transferred to a PC or laptop via the USB interface. The user-friendly data acquisition and analysis software is supplied free along with the data logger.
The basic specification of the MSR160 includes four analogue inputs. In addition you can also record temperature, humidity, pressure and attitude. If required, you can also connect external sensors in place of the internal ones (temperature, humidity or pressure), maximum two pieces.
With a few clicks you are able to select your desired MSR160.
Housing |
Technical data | Item no. | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() Standard IP 60 PC, not encapsulated |
|
160B7 Error |
||||||||||||||||||||||||||||
![]() Waterproof IP 67 PC, encapsulated |
160B8 Error |
Analogue inputs | Inputs | Input configuration | Item no. |
---|---|---|---|
![]() Including alarm output and input for starting and stopping data recording. |
4 analogue inputs (resolution: 12 bit) |
Select the number of inputs for the respective input configuration: (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0.5...4.5 V / 0...5.0 V (5) 0...10.0 V / 1.0...6.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V |
Exxxx |
You can select various internal as well external sensors.
Measured parameter / Measuring/storage rate |
Working range / Accuracy |
Internal sensor |
External sensor (according to cable length) | ||
---|---|---|---|---|---|
0.20 m | 1.00 m | 1.60 m | |||
Temperature 1/s to every 12 h |
external: -55...+125 °C internal: -20...+65 °C ±0.5 °C (-10...+65 °C) ±2 °C (-55...+125 °C) |
Item no. T2 Error |
Item no. FT2/020 Error |
Item no. FT2/100 Error |
Item no. FT2/160 Error |
Relative humidity with integrated temperature 1/s to every 12 h |
0...100 % rel. humidity extern: -20...+85 °C intern: -20...+65 °C ±2 % rel. humidity (10...85 %, 0...+40 °C) ±4 % rel. Feuchte (85...95 %, 0...+40 °C) |
Item no. H Error |
Item no. FH/020 Error |
Item no. FH/100 Error |
Item no. FH/160 Error |
Air pressure absolute, with integrated temperature 1/s to every 12 h |
0...2000 mbar absolute extern: -20...+85 °C intern: -20...+65 °C ±2,5 mbar (750...1100 mbar absolute, +25 °C) |
Item no. P Error |
Item no. FP/020 Error |
Item no. FP/100 Error |
Item no. FP/160 Error |
0...14 bar absolute -20...+65 °C ±50 mbar (1...10 bar abs., +25 °C) |
Item no. P2 Error |
Item no. FP2/020 Error |
Item no. FP2/100 Error |
Item no. FP2/160 Error |
|
Attitude 1/s to every 12 h |
±15 g -20...+65 °C ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C) |
Item no. A Error |
Item no. FA/020 Error |
Item no. FA/100 Error |
Item no. FA/160 Error |
Light 1/s to every 12 h |
0...65 000 lx max. sensitivity at 500 nm |
Item no. L2 Error |
Item no. FL2/020 Error |
Item no. FL2/100 Error |
Item no. FL2/160 Error |
Please order the expansion slot for plugging-in a standard microSD card here. | Item no. |
---|---|
Expansion slot for microSD card (includes one formatted and ready for use ≥4GB microSD card). Please note that this expansion slot with plugged-in microSD-card only meets the protection category IP60. |
N10006 Error |