Wireless Data Logger with Bluetooth: MSR145WD

data logger with app · temperature, humidity, fluid pressure, air pressure, acceleration, strain gauges and more · NEW: interchangeable FlexSensors

The MSR145WD wireless data logger, the size of a thumb and equipped with Bluetooth function, has a storage capacity of one million measured values. The versatile mini logger can be used to wirelessly monitor measurement data, quickly read measured values and transfer them to the MSR SmartCloud if required.

General functions

Bluetooth functions

Configure your own custom MSR145WD variant here!

With a few clicks you are able to select your desired MSR145WD.

  1. Select the housing and the corresponding battery.
  2. Select the configuration.
  3. Choose the FlexSensors if required.
  4. Do you require a base station to transmit the measured values to the MSR SmartCloud?
  5. The use of MSR SmartCloud.
  6. General technical data of the MSR145WD.

1. Select the housing and the corresponding battery.

Housing Type and battery Picture Size & weight Medium Sheat
material
Item no.
Standard
IP 60
Design housing
with 230 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 17 x 57 mm
(W x H x L)
approx. 27 g
Air PC, not
encapsulated
145WDB25
Error
Design housing
with 1000 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 25 x 57 mm
(W x H x L)
approx. 43 g
Air PC, not
encapsulated
145WDB23
Error
Waterproof
IP 67
Design housing
with 230 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 17 x 57 mm
(W x H x L)
approx. 36 g
Air,
various liquids
PC,
encapsulated
145WDB26
Error
Design housing
with 1000 mAh battery,
OLED display and
Bluetooth Low Energy
35 x 25 x 57 mm
(W x H x L)
approx. 62 g
Air,
various liquids
PC,
encapsulated
145WDB22
Error

2. Select the configuration.

You can select various internal sensors as well as up to five external sensors or connectors.

Measured parameter /
Measurement/
storage rate
Technical data Internal External (according to cable length)
0.20 m 1.00 m 1.60 m
Temperature

1/s to every 12 h
Working range::
external: -40...+125 °C
internal: -20...+65 °C

Max. deviation:
±0.2 °C (-10...+50 °C)
±1 °C (-40...+125 °C)
Item no. T5
Error
Item no. FT5/020
Error

Item no. FT5/100
Error

Item no. FT5/160
Error

Connector for thermal
element of Type K

(without sensor)


1/s to every 12 h
Working range:
-200...+1350 °C
only available
externally
Item no. FT3/020
Error

Item no. FT3/100
Error

Item no. FT3/160
Error

Humidity
with integrated
temperature

1/s to every 12 h
Working range:
0...100 % rel. humidity
external: -40...+125 °C
internal: -20...+65 °C

Max. deviation:
±1.8 % rel. humidity
(10...85 %, 0...+40 °C)
±4 % rel. humidity
(85...95 %, 0...+40 °C)
Item no. H2
Error
Item no. FH2/020
Error

Item no. FH2/100
Error

Item no. FH2/160
Error

Air pressure absolute,
with integrated
temperature

1/s to every 12 h
Working range:
10...2000 mbar absolute
external: -40...+85 °C
internal: -20...+65 °C

Max. deviation:
±2 mbar
(750...1100 mbar absolute,
+25 °C)
Item no. P5
Error
Item no. FP10/020
Error

Item no. FP10/100
Error

Item no. FP10/160
Error

Working range:
0...14 bar absolute
-20...+65 °C

Max. deviation:
±50 mbar
(1...10 bar abs., +25 °C)
only available
externally
Item no. FP7/020
Error

Item no. FP7/100
Error

Item no. FP7/160
Error

Fluid pressure
with integrated
temperature

1/s to every 12 h

Material in contact with
media:
  • Stainless Steel
    AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-rings:
    Viton® 70° Shore
Working range:
-1000...3000 mbar relative
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
only available
externally
Item no. FP9/020
Error

Item no. FP9/100
Error

Item no. FP9/160
Error

Working range:
0...3000 mbar absolute
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
only available
externally
Item no. FP3/020
Error

Item no. FP3/100
Error

Item no. FP3/160
Error

Working range:
0...30 bar absolute
-20...+85 °C

Max. deviation:
±0.3 bar (1% FS)
only available
externally
Item no. FP4/020
Error

Item no. FP4/100
Error

Item no. FP4/160
Error

Working range:
0...400 bar absolute
-20...+85 °C

Max. deviation:
±4 bar (1% FS)
only available
externally
Item no. FP8/020
Error

Item no. FP8/100
Error

Item no. FP8/160
Error

Working range:
0...1000 bar absolute
-20...+85 °C

Max. deviation:
±10 bar (1% FS)
only available
externally
Item no. FP12/020
Error

Item no. FP12/100
Error

Item no. FP12/160
Error

3-axis-acceleration
(static)

1/s to every 12 h
Working range:
-15...+15 g
-20...+65 °C

Max. deviation:
±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
Item no. A
Error
Item no. FA/020
Error
Item no. FA/100
Error
Item no. FA/160
Error
Light

1/s to every 12 h
Working range:
0...65 000 lx

Max. sensitivity
at 500 nm
Item no. L2
Error
Item no. FL2/020
Error

Item no. FL2/100
Error

Item no. FL2/160
Error

Connection for
strain gauges
Characteristics:
  • full bridge
  • rated output 1 mV/V
  • bridge voltage 3 V
only available
externally
Item no. FD/020
Error

Item no. FD/100
Error

Item no. FD/160
Error

Analogue inputs
(resolution: 12 bit)

1/s to every 12 h
Input configuration:




only available
externally
Exxxx/020
Error
Exxxx/100
Error
Exxxx/160
Error
Input configuration:




only available
externally
Exxxx/020
Error
Exxxx/100
Error
Exxxx/160
Error
Control terminal Characteristics:
  • Alarm output
  • Input for starting and
    stopping data recording
  • 3 V voltage output
only available
externally
Item no. FY/020
Error
Item no. FY/100
Error
Item no. FY/160
Error
FlexConnector
(only combined with
B22 and B23 cases)
The appropriate
FlexSensors are below
presented for choice.
only available
externally
Item no. FX/020
Error
Item no. FX/100
Error
Item no. FX/160
Error

3. Choose the FlexSensors if required.

If you have selected a FlexConnector or already own an MSR145WD data logger with a FlexConnector, you can order suitable sensors here. Please note only one interchangeable FlexSensor can be connected to the FlexConnector at a time.

Measured parameter /
Measurement/
storage rate
Technical data Item no.
Temperature

1/s to every 12 h
Working range:
-40...+125 °C

Max. deviation:
±0.2 °C (-10...+50 °C)
±1 °C (-40...+125 °C)
FXT5/160
Error
Humidity
with integrated
temperature

1/s to every 12 h
Working range:
0...100 % rel. humidity
-40...+125 °C

Max. deviation:
±1,8 % relative humidity (10...85 %, 0...+40 °C)
±4 % relative humidity (85...95 %, 0...+40 °C)
FXH2/160
Error
Fluid pressure
with integrated
temperature

1/s to every 12 h

Material in contact with
media:
  • Stainless Steel
    AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-rings:
    Viton® 70° Shore
Working range:
-1000...3000 mbar relative
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
FXP9/160
Error
Working range:
0...3000 mbar absolute
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
FXP3/160
Error
Working range:
0...30 bar absolute
-20...+85 °C

Max. deviation:
±0.3 bar (1% FS)
FXP4/160
Error
Working range:
0...400 bar absolute
-20...+85 °C

Max. deviation:
±4 bar (1% FS)
FXP8/160
Error
Working range:
0...1000 bar absolute
-20...+85 °C

Max. deviation:
±10 bar (1% FS)
FXP12/160
Error
3-axis-acceleration
with Fast Peak
(800 Hz)

1/s to every 12 h
Working range:
-15...+15 g
-20...+65 °C

Max. deviation:
±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
FXA4/160
Error
Light

1/s to every 12 h
Working range:
0...65 000 lx

Max. sensitivity at 500 nm
FXL2/160
Error

4. Do you require a base station to transmit the measured values to the MSR SmartCloud?

MSR base station Description Item no.
The BLE receiver box acts a gateway which allows the automatic data transfer of several MSR145WD data loggers to the MSR Smart Cloud.

The BLE receiver box acts a gateway which allows the automatic data transfer of several MSR145WD data loggers to the MSR SmartCloud.

N10115
Error

5. The use of MSR SmartCloud.

The cloud solution managed by MSR Electronics GmbH records data measured by MSR data loggers in a database. Through online access to MSR SmartCloud you are able to gain insight into your measured data, manage it, and create alert messages. When ordering the MSR145WD data logger you will automatically receive the access code to MSR SmartCloud.

Service Description
MSR SmartCloud Free access to MSR SmartCloud when you purchase the MSR145WD data logger.
Data capacity up to 100 000 measurements, Data memory up to three months.

6. General technical data of the MSR145WD.

Memory capacity: Over 1 000 000 measured values.
Key button: With the button you can activate and deactivate the display, the BLE-module and the data recording.
LED:  
Blue:
Red:
Yellow:
Record indicator
Alarm indicator
Battery charge indicator
Power supply: Lithium-polymer battery, rechargeable via the USB connection
OLED display: High-contrast, brilliant OLED (organic light-emitting diode) colour display
to show data and graphical charts, resolution 96 x 64 pixels.
Interface: USB, Bluetooth Low Energy
PC software: MSR Setup, Reader, Viewer and Online software, System requirements: Windows 7 or higher, USB port
Operation conditions:
Temperature: -20...+65 °C
Storage conditions:
Temperature:
Humidity:
+5...+45 °C (ideal storage conditions for the battery)
10...95 % relative humidity, non-condensing
Standards: The MSR145WD complies with EU-Directives RoHS/WEEE.

Your selection:

Price: (USD)
Item no.: