Wireless monitoring of measurement data and rapid reading of measured values – this ease of use is offered by the new MSR145WD wireless data logger. The mini-logger is equipped with Bluetooth Low Energy, a bright OLED graphic display and the optional web-based service MSR SmartCloud for data monitoring from any location.
The BLE wireless radio link is particularly advantageous for applications that require monitoring of measured data from locations that are difficult to access, such as machine rotations. BLE allows the user immediate data visualisation irrespective of the location. You can recall the measured values on your smartphone, receive alarm messages via MSR SmartCloud and, if required, share data from multiple MSR145WD data loggers with your team any time.
Technical data Bluetooth Low Energy |
|
---|---|
![]() |
|
For a compact representation of data and graphic charts, your MSR145WD is equipped with a colour OLED display. The high screen resolution facilitates easy reading of measured values, even in total darkness and from virtually any viewing angle. The display is switched on and off manually; the desired display data can be configured in the MSR PC software.
Technical data OLED display |
|
---|---|
![]() |
|
With a few clicks you are able to select your desired MSR145WD.
Housing | Type and battery | Picture | Size & weight | Medium | Sheat material |
Item no. |
---|---|---|---|---|---|---|
Standard IP 60 |
Design housing with 230 mAh battery, OLED display and Bluetooth Low Energy |
![]() |
35 x 17 x 57 mm (W x H x L) approx. 27 g |
Air | PC, not encapsulated |
145WDB25 Error |
Design housing with 900 mAh battery, OLED display and Bluetooth Low Energy |
![]() |
35 x 25 x 57 mm (W x H x L) approx. 43 g |
Air | PC, not encapsulated |
145WDB23 Error |
|
Waterproof IP 67 |
Design housing with 230 mAh battery, OLED display and Bluetooth Low Energy |
![]() |
35 x 17 x 57 mm (W x H x L) approx. 36 g |
Air, various liquids |
PC, encapsulated |
145WDB26 Error |
Design housing with 900 mAh battery, OLED display and Bluetooth Low Energy |
![]() |
35 x 25 x 57 mm (W x H x L) approx. 62 g |
Air, various liquids |
PC, encapsulated |
145WDB22 Error |
You can select various internal sensors as well as up to five external sensors or connectors.
Measured parameter / Measurement/ storage rate |
Technical data | Internal | External (according to cable length) | ||
---|---|---|---|---|---|
0.20 m | 1.00 m | 1.60 m | |||
Temperature 1/s to every 12 h |
Working range:: external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±0.2 °C (-10...+50 °C) ±1 °C (-40...+125 °C) |
Item no. T5 Error |
Item no. FT5/020 Error |
Item no. FT5/100 Error |
Item no. FT5/160 Error |
Connector for thermal element of Type K (without sensor) 1/s to every 12 h |
Working range: -200...+1350 °C |
only available externally |
Item no. FT3/020 Error |
Item no. FT3/100 Error |
Item no. FT3/160 Error |
Humidity with integrated temperature 1/s to every 12 h |
Working range: 0...100 % rel. humidity external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±1.8 % rel. humidity (10...85 %, 0...+40 °C) ±4 % rel. humidity (85...95 %, 0...+40 °C) |
Item no. H2 Error |
Item no. FH2/020 Error |
Item no. FH2/100 Error |
Item no. FH2/160 Error |
Air pressure absolute, with integrated temperature 1/s to every 12 h |
Working range: 10...2000 mbar absolute external: -40...+85 °C internal: -20...+65 °C Max. deviation: ±2 mbar (750...1100 mbar absolute, +25 °C) |
Item no. P5 Error |
Item no. FP5/020 Error |
Item no. FP5/100 Error |
Item no. FP5/160 Error |
Working range: 0...14 bar absolute -20...+65 °C Max. deviation: ±50 mbar (1...10 bar abs., +25 °C) |
only available externally |
Item no. FP7/020 Error |
Item no. FP7/100 Error |
Item no. FP7/160 Error |
|
Fluid pressure with integrated temperature 1/s to every 12 h Material in contact with media:
|
Working range: -1000...3000 mbar relative -20...+85 °C Max. deviation: ±30 mbar (1% FS) |
only available externally |
Item no. FP9/020 Error |
Item no. FP9/100 Error |
Item no. FP9/160 Error |
Working range: 0...3000 mbar absolute -20...+85 °C Max. deviation: ±30 mbar (1% FS) |
only available externally |
Item no. FP3/020 Error |
Item no. FP3/100 Error |
Item no. FP3/160 Error |
|
Working range: 0...30 bar absolute -20...+85 °C Max. deviation: ±0.3 bar (1% FS) |
only available externally |
Item no. FP4/020 Error |
Item no. FP4/100 Error |
Item no. FP4/160 Error |
|
Working range: 0...400 bar absolute -20...+85 °C Max. deviation: ±4 bar (1% FS) |
only available externally |
Item no. FP8/020 Error |
Item no. FP8/100 Error |
Item no. FP8/160 Error |
|
Working range: 0...1000 bar absolute -20...+85 °C Max. deviation: ±10 bar (1% FS) |
only available externally |
Item no. FP12/020 Error |
Item no. FP12/100 Error |
Item no. FP12/160 Error |
|
3-axis-acceleration (static) 1/s to every 12 h |
Working range: -15...+15 g -20...+65 °C Max. deviation: ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C) |
Item no. A Error |
Item no. FA/020 Error |
Item no. FA/100 Error |
Item no. FA/160 Error |
Light 1/s to every 12 h |
Working range: 0...65,000 lx Max. sensitivity at 500 nm |
Item no. L2 Error |
Item no. FL2/020 Error |
Item no. FL2/100 Error |
Item no. FL2/160 Error |
Connection for strain gauges |
Characteristics:
|
only available externally |
Item no. FD/020 Error |
Item no. FD/100 Error |
Item no. FD/160 Error |
Analogue inputs (resolution: 12 bit) 1/s to every 12 h |
Input configuration: |
only available externally |
Exxxx/020 Error |
Exxxx/100 Error |
Exxxx/160 Error |
Input configuration: |
only available externally |
Exxxx/020 Error |
Exxxx/100 Error |
Exxxx/160 Error |
|
Control terminal | Characteristics:
|
only available externally |
Item no. FY/020 Error |
Item no. FY/100 Error |
Item no. FY/160 Error |
Flex-Connector (only combined with B22 and B23 cases) |
The appropriate flex sensors are below presented for choice. |
only available externally |
Item no. FX/020 Error |
Item no. FX/100 Error |
Item no. FX/160 Error |
You have selected a Flex-Connector or if you already own a MSR145W2D data logger with a Flex-Connector you can choose the corresponding sensors here.
Measured parameter / Measurement/ storage rate |
Technical data | Item no. |
---|---|---|
Humidity with integrated 1/s to every 12 h |
Working range: 0...100 % rel. humidity -40...+125 °C Max. deviation: ±1,8 % relative humidity (10...85 %, 0...+40 °C) ±4 % relative humidity (85...95 %, 0...+40 °C) |
FXH2/160 Error |
Light 1/s to every 12 h |
Working range: 0...65 000 lx Max. sensitivity at 500 nm |
FXL2/160 Error |
Temperature 1/s to every 12 h |
Working range: -40...+125 °C Max. deviation: ±0.2 °C (-10...+50 °C) ±1 °C (-40...+125 °C) |
FXT5/160 Error |
MSR base station | Description | Item no. |
---|---|---|
![]() |
The BLE receiver box acts a gateway which allows the automatic data transfer of several MSR145WD data loggers to the MSR SmartCloud. |
N10115 Error |
The cloud solution managed by MSR Electronics GmbH records data measured by MSR data loggers in a database. Through online access to MSR SmartCloud you are able to gain insight into your measured data, manage it, and create alert messages. When ordering the MSR145W2D data logger you will automatically receive the access code to MSR SmartCloud.
Service | Description |
---|---|
MSR SmartCloud | Free access to MSR SmartCloud when you purchase the MSR145W2D data logger. Data capacity up to 100,000 measurements, Data memory up to three months. |
Memory capacity: | Over 1 000 000 measured values. | |
Key button: | Set bookmark or start and stop recording. | |
LED: | ||
Blue: Red: Yellow: |
Record indicator Alarm indicator Battery charge indicator |
|
Power supply: | Lithium-polymer battery, rechargeable via the USB connection | |
OLED display: | High-contrast, brilliant OLED (organic light-emitting diode) colour display to show data and graphical charts, resolution 96 x 64 pixels. |
|
Interface: | USB | |
PC software: | Free Setup, Reader, Viewer and Online software (Windows 7/8/10) to record and evaluate data. All measurement parameters can be rapidly transferred to a PC via USB connection both during the measurement operation and once the measurement task has been completed. | |
Operation conditions: | ||
Temperature: | -20...+65 °C | |
Storage conditions: | ||
Temperature: Humidity: |
+5...+45 °C (ideal storage conditions for the battery) 10...95 % relative humidity, non-condensing |
|
Standards: | The MSR145W2D complies with EU-Directives RoHS/WEEE. |