The MSR145WD wireless data logger, the size of a thumb and equipped with Bluetooth function, has a storage capacity of one million measured values. The versatile mini logger can be used to wirelessly monitor measurement data, quickly read measured values and transfer them to the MSR SmartCloud if required.
With a few clicks you are able to select your desired MSR145WD.
Housing | Type and battery | Picture | Size & weight | Medium | Sheat material |
Item no. |
---|---|---|---|---|---|---|
Standard IP 60 |
Design housing with 230 mAh battery, OLED display and Bluetooth Low Energy |
35 x 17 x 57 mm (W x H x L) approx. 27 g |
Air | PC, not encapsulated |
145WDB25 Error |
|
Design housing with 1000 mAh battery, OLED display and Bluetooth Low Energy |
35 x 25 x 57 mm (W x H x L) approx. 43 g |
Air | PC, not encapsulated |
145WDB23 Error |
||
Waterproof IP 67 |
Design housing with 230 mAh battery, OLED display and Bluetooth Low Energy |
35 x 17 x 57 mm (W x H x L) approx. 36 g |
Air, various liquids |
PC, encapsulated |
145WDB26 Error |
|
Design housing with 1000 mAh battery, OLED display and Bluetooth Low Energy |
35 x 25 x 57 mm (W x H x L) approx. 62 g |
Air, various liquids |
PC, encapsulated |
145WDB22 Error |
You can select various internal sensors as well as up to five external sensors or connectors.
Measured parameter / Measurement/ storage rate |
Technical data | Internal | External (according to cable length) | ||
---|---|---|---|---|---|
0.20 m | 1.00 m | 1.60 m | |||
Temperature 1/s to every 12 h |
Working range:: external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±0.2 °C (-10...+50 °C) ±1 °C (-40...+125 °C) |
Item no. T5 Error |
Item no. FT5/020 Error |
Item no. FT5/100 Error |
Item no. FT5/160 Error |
Connector for thermal element of Type K (without sensor) 1/s to every 12 h |
Working range: -200...+1350 °C |
only available externally |
Item no. FT3/020 Error |
Item no. FT3/100 Error |
Item no. FT3/160 Error |
Humidity with integrated temperature 1/s to every 12 h |
Working range: 0...100 % rel. humidity external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±1.8 % rel. humidity (10...85 %, 0...+40 °C) ±4 % rel. humidity (85...95 %, 0...+40 °C) |
Item no. H2 Error |
Item no. FH2/020 Error |
Item no. FH2/100 Error |
Item no. FH2/160 Error |
Air pressure absolute, with integrated temperature 1/s to every 12 h |
Working range: 10...2000 mbar absolute external: -40...+85 °C internal: -20...+65 °C Max. deviation: ±2 mbar (750...1100 mbar absolute, +25 °C) |
Item no. P5 Error |
Item no. FP10/020 Error |
Item no. FP10/100 Error |
Item no. FP10/160 Error |
Working range: 0...14 bar absolute -20...+65 °C Max. deviation: ±50 mbar (1...10 bar abs., +25 °C) |
only available externally |
Item no. FP7/020 Error |
Item no. FP7/100 Error |
Item no. FP7/160 Error |
|
Fluid pressure with integrated temperature 1/s to every 12 h Material in contact with media:
|
Working range: -1000...3000 mbar relative -20...+85 °C Max. deviation: ±30 mbar (1% FS) |
only available externally |
Item no. FP9/020 Error |
Item no. FP9/100 Error |
Item no. FP9/160 Error |
Working range: 0...3000 mbar absolute -20...+85 °C Max. deviation: ±30 mbar (1% FS) |
only available externally |
Item no. FP3/020 Error |
Item no. FP3/100 Error |
Item no. FP3/160 Error |
|
Working range: 0...30 bar absolute -20...+85 °C Max. deviation: ±0.3 bar (1% FS) |
only available externally |
Item no. FP4/020 Error |
Item no. FP4/100 Error |
Item no. FP4/160 Error |
|
Working range: 0...400 bar absolute -20...+85 °C Max. deviation: ±4 bar (1% FS) |
only available externally |
Item no. FP8/020 Error |
Item no. FP8/100 Error |
Item no. FP8/160 Error |
|
Working range: 0...1000 bar absolute -20...+85 °C Max. deviation: ±10 bar (1% FS) |
only available externally |
Item no. FP12/020 Error |
Item no. FP12/100 Error |
Item no. FP12/160 Error |
|
3-axis-acceleration (static) 1/s to every 12 h |
Working range: -15...+15 g -20...+65 °C Max. deviation: ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C) |
Item no. A Error |
Item no. FA/020 Error |
Item no. FA/100 Error |
Item no. FA/160 Error |
Light 1/s to every 12 h |
Working range: 0...65 000 lx Max. sensitivity at 500 nm |
Item no. L2 Error |
Item no. FL2/020 Error |
Item no. FL2/100 Error |
Item no. FL2/160 Error |
Connection for strain gauges |
Characteristics:
|
only available externally |
Item no. FD/020 Error |
Item no. FD/100 Error |
Item no. FD/160 Error |
Analogue inputs (resolution: 12 bit) 1/s to every 12 h |
Input configuration: |
only available externally |
Exxxx/020 Error |
Exxxx/100 Error |
Exxxx/160 Error |
Input configuration: |
only available externally |
Exxxx/020 Error |
Exxxx/100 Error |
Exxxx/160 Error |
|
Control terminal | Characteristics:
|
only available externally |
Item no. FY/020 Error |
Item no. FY/100 Error |
Item no. FY/160 Error |
FlexConnector (only combined with B22 and B23 cases) |
The appropriate FlexSensors are below presented for choice. |
only available externally |
Item no. FX/020 Error |
Item no. FX/100 Error |
Item no. FX/160 Error |
If you have selected a FlexConnector or already own an MSR145WD data logger with a FlexConnector, you can order suitable sensors here. Please note only one interchangeable FlexSensor can be connected to the FlexConnector at a time.
Measured parameter / Measurement/ storage rate |
Technical data | Item no. |
---|---|---|
Temperature 1/s to every 12 h |
Working range: -40...+125 °C Max. deviation: ±0.2 °C (-10...+50 °C) ±1 °C (-40...+125 °C) |
FXT5/160 Error |
Humidity with integrated temperature 1/s to every 12 h |
Working range: 0...100 % rel. humidity -40...+125 °C Max. deviation: ±1,8 % relative humidity (10...85 %, 0...+40 °C) ±4 % relative humidity (85...95 %, 0...+40 °C) |
FXH2/160 Error |
Fluid pressure with integrated temperature 1/s to every 12 h Material in contact with media:
|
Working range: -1000...3000 mbar relative -20...+85 °C Max. deviation: ±30 mbar (1% FS) |
FXP9/160 Error |
Working range: 0...3000 mbar absolute -20...+85 °C Max. deviation: ±30 mbar (1% FS) |
FXP3/160 Error |
|
Working range: 0...30 bar absolute -20...+85 °C Max. deviation: ±0.3 bar (1% FS) |
FXP4/160 Error |
|
Working range: 0...400 bar absolute -20...+85 °C Max. deviation: ±4 bar (1% FS) |
FXP8/160 Error |
|
Working range: 0...1000 bar absolute -20...+85 °C Max. deviation: ±10 bar (1% FS) |
FXP12/160 Error |
|
3-axis-acceleration with Fast Peak (800 Hz) 1/s to every 12 h |
Working range: -15...+15 g -20...+65 °C Max. deviation: ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C) |
FXA4/160 Error |
Light 1/s to every 12 h |
Working range: 0...65 000 lx Max. sensitivity at 500 nm |
FXL2/160 Error |
MSR base station | Description | Item no. |
---|---|---|
The BLE receiver box acts a gateway which allows the automatic data transfer of several MSR145WD data loggers to the MSR SmartCloud. |
N10115 Error |
The cloud solution managed by MSR Electronics GmbH records data measured by MSR data loggers in a database. Through online access to MSR SmartCloud you are able to gain insight into your measured data, manage it, and create alert messages. When ordering the MSR145WD data logger you will automatically receive the access code to MSR SmartCloud.
Service | Description |
---|---|
MSR SmartCloud | Free access to MSR SmartCloud when you purchase the MSR145WD data logger. Data capacity up to 100 000 measurements, Data memory up to three months. |
Memory capacity: | Over 1 000 000 measured values. | |
Key button: | With the button you can activate and deactivate the display, the BLE-module and the data recording. | |
LED: | ||
Blue: Red: Yellow: |
Record indicator Alarm indicator Battery charge indicator |
|
Power supply: | Lithium-polymer battery, rechargeable via the USB connection | |
OLED display: | High-contrast, brilliant OLED (organic light-emitting diode) colour display to show data and graphical charts, resolution 96 x 64 pixels. |
|
Interface: | USB, Bluetooth Low Energy | |
PC software: | MSR Setup, Reader, Viewer and Online software, System requirements: Windows 7 or higher, USB port | |
Operation conditions: | ||
Temperature: | -20...+65 °C | |
Storage conditions: | ||
Temperature: Humidity: |
+5...+45 °C (ideal storage conditions for the battery) 10...95 % relative humidity, non-condensing |
|
Standards: | The MSR145WD complies with EU-Directives RoHS/WEEE. |