MSR145: Data Logger for Temperature, Humidity, Air Pressure, Liquid Pressure, Acceleration, Light

multifunctional data logger · large selection of sensors · various battery and housing variants · up to over 1 bn measured values · air cargo approved

With the compact MSR145 mini data logger, you can measure and store up to 5 different measured variables such as temperature, humidity, air or liquid pressure, position/3-axis acceleration and light simultaneously. The MSR145 quality data logger stores over 2 000 000 measured values – with optional microSD card over one billion measured values – and is ideal for long-term measurements.

Product features universal data logger MSR145

With a few clicks you are able to select your desired MSR145.

  1. Select the housing and the corresponding battery.
  2. Select the configuration.
  3. Would you like to expand the memory capacity to over 1 billion measured values?
  4. General technical data of the MSR145 data logger

1. Select the housing and the corresponding battery.

Housing Type and battery Picture Size & weight Medium Sheat
material
Item no.
Standard
IP 60
Design housing
with 230 mAh battery
MSR145S 27 x 16 x 53 mm
(W x H x L)
approx. 20 g
Air PC, not
encapsulated
145B15
Error
Design housing
with 1000 mAh battery
MSR145 900 mAh 39 x 23 x 72 mm
(W x H x L)
approx. 56 g
Air PC, not
encapsulated
145B7
Error
Waterproof
IP 67
Silicon tube
with 230 mAh battery
MSR145W 20 x 14 x 62 mm
(W x H x L)
approx. 18 g
Air,
various liquids
Silicon,
encapsulated
145B4
Error
Design housing
with 230 mAh battery
MSR145WS 27 x 16 x 53 mm
(W x H x L)
approx. 27 g
Air,
various liquids
PC,
encapsulated
145B16
Error
Design housing
with 1000 mAh battery
MSR145 900 mAh 39 x 23 x 72 mm
(W x H x L)
approx. 64 g
Air,
various liquids
PC,
encapsulated
145B8
Error

2. Select the configuration.

You can select various internal sensors as well as up to five external sensors or connectors.

Measured parameter /
Measurement/
storage rate
Technical data Internal External (according to cable length)
0.20 m 1.00 m 1.60 m
Temperature

1/s to every 12 h
Working range:
external: -55...+125 °C

Max. deviation:
±0.5 °C (-10...+65 °C)
±2 °C (-55...+125 °C)
only available
externally
Item no. FT2/020
Error

Item no. FT2/100
Error

Item no. FT2/160
Error

Working range:
external: -40...+125 °C
internal: -20...+65 °C

Max. deviation:
±0.2 °C (-10...+50 °C)
±1 °C (-40...+125 °C)
Item no. T9
Error
Item no. FT5/020
Error

Item no. FT5/100
Error

Item no. FT5/160
Error

Connector for thermal
element of Type K

(without sensor)


4/s* to every 12 h
*(1/s in combination
with A4 sensor)
Working range:
-200...+1350 °C
only available
externally
Item no. FT3/020
Error

Item no. FT3/100
Error

Item no. FT3/160
Error

Humidity
with integrated
temperature

1/s to every 12 h
Working range:
0...100 % rel. humidity
external: -20...+85 °C
internal: -20...+65 °C

Max. deviation:
±2 % rel. humidity
(10...85 %, 0...+40 °C)
±4 % rel. humidity
(85...95 %, 0...+40 °C)
Item no. H3
Error
Item no. FH2/020
Error

Item no. FH2/100
Error

Item no. FH2/160
Error

Air pressure absolute,
with integrated
temperature

Internal:
1/s to every 12 h
External:
10/s* to every 12 h
*(1/s in combination
with A4 sensor)
Working range:
10...2000 mbar absolute
external: -40...+85 °C
internal: -20...+65 °C

Max. deviation:
±2 mbar (1% FS)
(750...1100 mbar absolute,
+25 °C)
Item no. P5
Error
Item no. FP5/020
Error

Item no. FP5/100
Error

Item no. FP5/160
Error

Working range:
10...2000 mbar absolute
external: -40...+85 °C

Max. deviation:
±2 mbar (1% FS)
(750...1100 mbar absolute,
+25 °C)
only available
externally
Item no. FP10/020
Error

Item no. FP10/100
Error

Item no. FP10/160
Error

Working range:
0...14 bar absolute
-20...+65 °C

Max. deviation:
±50 mbar (1% FS)
(1...10 bar abs., +25 °C)
Item no. P7

only available
on request
Item no. FP7/020
Error

Item no. FP7/100
Error

Item no. FP7/160
Error

Fluid pressure
with integrated
temperature

Internal:
1/s to every 12 h
External:
10/s* to every 12 h
*(1/s in combination
with A4 sensor)

Material in contact
with media:
  • Stainless Steel AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-rings: Viton® 70° Sh
Working range:
-1000...3000 mbar relative
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
only available
externally
Item no. FP9/020
Error

Item no. FP9/100
Error

Item no. FP9/160
Error

Working range:
0...3000 mbar absolute
-20...+85 °C

Max. deviation:
±30 mbar (1% FS)
only available
externally
Item no. FP3/020
Error

Item no. FP3/100
Error

Item no. FP3/160
Error

Working range:
0...30 bar absolute
-20...+85 °C

Max. deviation:
±0.3 bar (1% FS)
only available
externally
Item no. FP4/020
Error

Item no. FP4/100
Error

Item no. FP4/160
Error

Working range:
0...400 bar absolute
-20...+85 °C

Max. deviation:
±4 bar (1% FS)
only available
externally
Item no. FP8/020
Error

Item no. FP8/100
Error

Item no. FP8/160
Error

Working range:
0...1000 bar absolute
-20...+85 °C

Max. deviation:
±10 bar (1% FS)
only available
externally
Item no. FP12/020
Error

Item no. FP12/100
Error

Item no. FP12/160
Error

3-axis-acceleration
(static)

50/s* to every 12 h
*(1/s in combination
with A4 sensor)
±15 g
-20...+65 °C

±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
Item no. A
Error
Item no. FA/020
Error
Item no. FA/100
Error
Item no. FA/160
Error
3-axis-acceleration
with Fast Peak (1 kHz)


50/s to every 12 h
Item no. A4
Error
Item no. FA4/020
Error
Item no. FA4/100
Error
Item no. FA4/160
Error
Light

1/s to every 12 h
Working range:
0...65 000 lx

Max. sensitivity
at 500 nm
Item no. L2
Error
Item no. FL2/020
Error

Item no. FL2/100
Error

Item no. FL2/160
Error

Connection for
strain gauges
Characteristics:
  • full bridge
  • rated output 1 mV/V
  • bridge voltage 3 V
only available
externally
Item no. FD/020
Error

Item no. FD/100
Error

Item no. FD/160
Error

Analogue inputs
(resolution: 12 bit)

50/s* to every 12 h
*(1/s in combination
with A4 sensor)
Input configuration:




only available
externally
Exxxx/020
Error
Exxxx/100
Error
Exxxx/160
Error
Control terminal Characteristics:
  • Alarm output
  • Input for starting and
    stopping data recording
  • 3 V voltage output
only available
externally
Item no. FY/020
Error
Item no. FY/100
Error
Item no. FY/160
Error

3. Would you like to expand the memory capacity to over 1 billion measured values?

Please order the expansion slot for plugging-in a standard microSD card here. Item no.
Expansion slot for microSD card (available only for design housing B7 and B8)

Please note that:
  • this expansion slot with plugged-in microSD card only meets the protection category IP60,
    even with the design housing B8,
  • one formatted and ready for use microSD card (≥4GB) is included.
N10006
Error

4. General technical data of the MSR145 data logger

Memory capacity: Over 2 million measurement values, with microSD card over 1 billion.
Push-button: Set bookmark or start and stop recording.
Power supply: Lithium-polymer battery, rechargeable via the USB port.
Interface: USB
PC software: Free MSR PC software for configuration and evaluation of the data. PC requirements: Windows 7 or higher.
Operating conditions:
Temperature: -20...+65 °C
Storage conditions:
Temperature:
Humidity:
+5...+45 °C (ideal storage conditions for the battery)
10...95 % relative humidity, non-condensing
Standards: The MSR145 complies with EU-Directives RoHS/WEEE.

Your selection:

Price: (USD)
Item no.: