This thumb-sized Swiss Quality MSR145 data logger records over 2 000 000 measured values – with an optional microSD card, even over a billion measured values – and is ideal for long-term measurements. It is capable of simultaneously measuring and recording a variety of measures such as temperature, humidity, pressure, 3-axis acceleration and light. All measured values can be rapidly transferred to a PC or laptop via the USB interface or microSD card for data analysis purposes.
You have the choice between different casings, battery capacities and sensors. Additionally, you can equip your MSR logger with analogue inputs (selectable input configuration). The analogue inputs allow you to connect individual, external sensors for different measuring tasks (e.g., CO2, conductivity, pH, etc.). In addition to your MSR145 data logger you will also receive the user-friendly software for data acquisition and analysis free of charge.
With a few clicks you are able to select your desired MSR145.
Housing | Type and battery | Picture | Size & weight | Medium | Sheat material |
Item no. |
---|---|---|---|---|---|---|
Standard IP 60 |
Design housing with 230 mAh battery |
![]() |
27 x 16 x 53 mm (W x H x L) approx. 20 g |
Air | PC, not encapsulated |
145B15 Error |
Design housing with 900 mAh battery |
![]() |
39 x 23 x 72 mm (W x H x L) approx. 56 g |
Air | PC, not encapsulated |
145B7 Error |
|
Waterproof IP 67 |
Silicon tube with 230 mAh battery |
![]() |
20 x 14 x 62 mm (W x H x L) approx. 18 g |
Air, various liquids |
Silicon, encapsulated |
145B4 Error |
Design housing with 230 mAh battery |
![]() |
27 x 16 x 53 mm (W x H x L) approx. 27 g |
Air, various liquids |
PC, encapsulated |
145B16 Error |
|
Design housing with 900 mAh battery |
![]() |
39 x 23 x 72 mm (W x H x L) approx. 64 g |
Air, various liquids |
PC, encapsulated |
145B8 Error |
Please select the sensors for your data logger here. For the measured parameters temperature, humidity and fluid pressure you can now choose whether you wish to provide your MSR145 data logger with more than one sensor of the same measured parameter. Please note the following restrictions for this option:
Can your desired sensor combination not be selected? Contact us for a customized fit.
Measured parameter / Measuring/storage rate |
Working range / Accuracy |
Internal sensor |
External sensor (according to cable length) | ||
---|---|---|---|---|---|
0.20 m | 1.00 m | 1.60 m | |||
Temperature 1/s to every 12 h |
-10...+58 °C ±0.1 °C (+5...+45 °C) ±0.2 °C (-10...+58 °C) |
only available externally |
Item no. FT/020 Error |
Item no. FT/100 Error |
Item no. FT/160 Error |
external: -55...+125 °C internal: -20...+65 °C ±0.5 °C (-10...+65 °C) ±2 °C (-55...+125 °C) |
Item no. T2 Error |
Item no. FT2/020 Error |
Item no. FT2/100 Error |
Item no. FT2/160 Error |
|
Connector for thermal element of Type K (without sensor) Cannot be selected at the same time as the temperature sensor. 1/s to every 12 h |
1 x -200...+1350 °C |
only available externally |
Item no. FT3/020 Error |
Item no. FT3/100 Error |
Item no. FT3/160 Error |
4 x -200...+1350 °C |
only available externally |
Item no. FT4/020 Error |
Item no. FT4/100 Error |
Item no. FT4/160 Error |
|
Humidity with integrated temperature 1/s to every 12 h |
0...100 % rel. humidity external: -20...+85 °C internal: -20...+65 °C ±2 % rel. humidity (10...85 %, 0...+40 °C) ±4 % rel. humidity (85...95 %, 0...+40 °C) |
Item no. H Error |
Item no. FH/020 Error |
Item no. FH/100 Error |
Item no. FH/160 Error |
Air pressure absolute, with integrated temperature 10/s to every 12 h |
0...2000 mbar absolute external: -20...+85 °C internal: -20...+65 °C ±2.5 mbar (750...1100 mbar absolute, +25 °C) |
Item no. P Error |
Item no. FP/020 Error |
Item no. FP/100 Error |
Item no. FP/160 Error |
0...14 bar absolute -20...+65 °C ±50 mbar (1...10 bar abs., +25 °C) |
Item no. P2 Error |
Item no. FP2/020 Error |
Item no. FP2/100 Error |
Item no. FP2/160 Error |
|
Fluid pressure with integrated temperature 20/s to every 12 h Material in contact with media:
|
0...3000 mbar absolute -20...+85 °C ±30 mbar |
only available externally |
Item no. FP3/020 Error |
Item no. FP3/100 Error |
Item no. FP3/160 Error |
0...30 bar absolute -20...+85 °C ±300 mbar |
only available externally |
Item no. FP4/020 Error |
Item no. FP4/100 Error |
Item no. FP4/160 Error |
|
3-axis-acceleration 50/s to every 12 h |
±15 g -20...+65 °C ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C) |
Item no. A Error |
Item no. FA/020 Error |
Item no. FA/100 Error |
Item no. FA/160 Error |
3-axis-acceleration with Fast Peak (1 kHz) 50/s to every 12 h |
Item no. A4 Error |
Item no. FA4/020 Error |
Item no. FA4/100 Error |
Item no. FA4/160 Error |
|
Light 1/s to every 12 h |
0...65 000 lx max. sensitivity at 500 nm |
Item no. L2 Error |
Item no. FL2/020 Error |
Item no. FL2/100 Error |
Item no. FL2/160 Error |
Should you wish to connect additional third-party external sensors to your MSR145 datalogger then please indicate here whether you require two or four analogue inputs.
Analogue inputs | Inputs | Input configuration | Item no. |
---|---|---|---|
![]() Including alarm output and input for starting and stopping data recording. Measurement/storage rate: 50/s to every 12 h Not available combinations:
|
2 analogue inputs (resolution: 12 Bit) |
0...3.0 V - standard |
E33 Error |
4 analogue inputs (resolution: 12 Bit) |
0...3.0 V - standard |
E3333 Error |
|
2 analogue inputs (resolution: 12 Bit) |
Select the number of inputs for the respective input configuration: (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0.5...4.5 V / 0...5.0 V (5) 0...10.0 V / 1.0...6.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V |
Exx Error |
|
4 analogue inputs (resolution: 12 Bit) |
Exxxx Error |
Please order the expansion slot for plugging-in a standard microSD card here. | Item no. |
---|---|
Expansion slot for microSD card (available only for design housing B7 and B8)
Please note that:
|
N10006 Error |
Memory capacity: | Over 2 000 000 measured values – expandable to over 1bn. | |
Key: | Set bookmark or start and stop recording. | |
LED: | ||
blue: red: yellow: |
Record indicator Alarm indicator Battery charge indicator |
|
Power supply: |
|
|
Options: | Charging station (USB hub) for 7 MSR145 (item number B47002) | |
Interface: | USB | |
PC software: | Free Setup, Reader, Viewer and Online software (Windows 7/8/10) to record and evaluate data. All measurement parameters can be rapidly transferred to a PC via USB connection both during the measurement operation and once the measurement task has been completed. Thanks to the integrated clock (RTC), data from as many MSR145 units as required can be synchronised and merged into a single data record. | |
Operating conditions: | ||
Temperature: | -20...+65 °C | |
Optimum storage conditions: | ||
Temperature: Humidity: |
+5...+45 °C (ideal storage conditions for the battery) 10...95 % relative humidity, non-condensing |
|
Standards: | The MSR145 complies with EU-Directives RoHS / WEEE. |