Edge: rising, falling or dual edge with adjustable hysteresis Window: signal enters or exits a user-defined voltage range Pulse width: a negative or positive pulse is wider or narrower than a set width, or inside/outside a range of widths Window pulse width: signal is inside or outside a voltage range for a set time Dropout: signal does not cross a voltage threshold for at least a set time Window dropout: signal does not enter or exit a voltage range for at least a set time Interval: time between two edges is greater or less than a set time, or inside/outside a time range Logic: arbitrary logic state of Channels A, B and EXT matches a user-defined pattern Runt pulse: signal crosses one voltage threshold and returns without crossing the other
Trigger sensitivity
Digital triggering provides 1 LSB accuracy up to full bandwidth of scope
Processor: Pentium II processor, or equivalent Memory: 64 MiB (XP) / 512 MiB (Vista) / 1 GiB (Win 7) Operating system: 32- or 64-bit edition of Microsoft Windows XP SP2, Vista or Windows 7 Ports: USB 2.0 compliant port
Recommended
Processor: 2 GHz Pentium IV processor, or equivalent Memory: 256 MiB (XP) / 1 GiB (Vista / Win 7) Operating system: 32- or 64-bit edition of Microsoft Windows XP SP2 (or above), Vista or Windows 7 Ports: USB 2.0 compliant port
Environmental
Operating environment
Temperature range
Humidity
0 °C to 45 °C (20 °C to 30 °C for quoted accuracy)
5% to 80% RH, non-condensing
Storage environment
Temperature range
Humidity
-20 °C to 60°C
5% to 95% RH, non-condensing
Physical Properties
Dimensions (including connectors)
210 x 135 x 40 mm (approx 8.2 x 5.3 x 1.5 in)
Weight
< 500 g (approx 1.1 lb)
Software
PicoScope 6 for Windows
PicoScope 6 is your complete test and measurement lab in one application. Features include: Capture modes: oscilloscope, spectrum and persistence. Channel maths: calculate the sum, difference, product, inverse or create your own custom function using standard arithmetic, exponential and trigonometric functions. Mask limiting testing: pass/fail, failure count, total count. Serial Decoding: decode data from a serial bus such as I²C. Automated measurements Scope mode: AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak-to-peak, rise time and rising rate. Spectrum mode: frequency at peak, amplitude at peak, average amplitude at peak, total power, total harmonic distortion (THD % and THD dB), total harmonic distortion plus noise (THD N), spurious-free dynamic range (SFDR), signal noise distortion to signal noise ratio (SINAD), signal to noise ratio (SNR) and intermodulation distortion (IMD). Export data formats: comma separated values (CSV), tab delimited (TXT), windows bitmap (BMP), graphics interchange format (GIF), portable network graphics (PNG), MATLAB 4 format (MAT). Full details for PicoScope 6
Software development kit
A growing collection of drivers and example code for various programming languages.
Language Support
Software
PicoScope 6
Full support for: English, Français, Deutsch, Italiano, Español Menus and dialogs only for: ä¸æ–‡ (简体), æ£é«”ä¸æ–‡ (ç¹é«”), ÄŒeština, Dansk, suomi, Ελληνικά, Magyar, 日本語, Norsk, Polski, Português, română, РуÑÑкий, Svenska, Türkçe
2 x MI007 probes, USB 2.0 cable, user manuals, software CD-ROM
PC interface
USB 2.0
Power requirements
Powered from USB port
Compliance
European EMC and LVD standards
FCC Rules Part 15 Class A
RoHS compliant
Warranty
5 years
Price
* US Dollar and Euro prices are approximate.
Note: quoted specifications apply when using PicoScope 6 software.
Need to know a specification not listed here? - just ask